Key performance benefits
Speed & productivity - hardware and software solutions working in harmony to transform cellular workflows

High sensitivity for efficient imaging of a range of samples from dim to bright assays

High resolution imaging for better segmentation and quantification of fine sub-cellular structures

Image restoration providing confocal-like image quality - advanced deconvolution options in 2D/3D acquisition modes greatly increase image accuracy in the lateral and axial dimensions

Rapid scanning of large areas and improved software functions facilitate efficient  detection of rare events

Automated filter, polychroic & objective changing for speed and convenience

Environmental control options and optimized hardware/software solutions enable a wide range of live cell studies with unstained or fluorescently labeled samples

Greatly enhanced functionality for slide imaging enables analysis of pathology samples, tissue arrays, cellular colonies and small organisms

Precision hardware and novel software solutions for 3D sectioning of thick samples such as spheroids or small organisms

Key functions for screening & research applications

Screening Applications
A combination of proprietary optics, a choice of large or standard chip camera and fast hardware and software autofocus delivers accurate, high-speed imaging for screening applications. A bright light source reduces exposure times to further maximize speed without compromising image quality and cell health while the rapid image restoration options allow confocal-like images to be obtained. System components have been subjected to rigorous accelerated lifetime testing using GE's six sigma performance guidelines to ensure reliability.
Key function
System feature
Applications
Speed

• Bright optics with powerful light source
• Fast hardware autofocus
• Fast on-line cell count function
• Rapid slide imaging
• Automated filter, polychroic &
  objective changing
• Large camera

• Compound screening
• Predicitive toxicology
• RNAi screening
• Lead optimization
• Slide-based arrays (tissue 
  microarrays, siRNAs etc)

Sensitivity

• Bright optics with powerful light source
• High-performance CCD camera
Range of objectives to suit sensitivity
  requirements of varied applications
• Rapid image resoration options - higher
  contrast & improved resolution even
  with dim samples
• Z-axis projection & image restoration
  combine to provide virtually extended
  depth of field for high magnifications

• Phenotypic profiling in screens
  requiring resolution of subcellular
  features
•  Rapid detection of low abundance
  probes & weak fluorescent sensors

Reliability

• Robust design & construction
• 
Stage accuracy & repeatability
• Rapid hardware & software autofocus
  ensure desired plane of interest is
  always in focus
• On-line cell counting to rapidly secure
  statistically reliable data collection 
• Large CCD camera maximizes data
  collection for statistically robust results

• Demanding screening applications with
  long run-times
• Shared facilities meeting the demands of
  multiple users or screening programs

Research Applications
A variety of innovative imaging features and a wide range of objectives (2× to 100×) gives exceptional flexibility for research use. The manual microscope mode allows you to work with images at full size and resolution, to zoom in and out and to manually adjust settings (e.g., filters, objectives, and z-height), and assess effects in real time.
Key function
System feature
Applications

Resolution
& sensitivity

• High NA/high magnification objectives
  provide thin optical section and maximum
  resolution in lateral & axial dimensions
• Bright optics with powerful light source to
  detect low abundance probes & weak
  fluorescent sensors
• Rapid image resoration options - higher
  contrast & improved resolution even with
  dim samples
• Z-axis projection & image restoration
  combine to provide virtually extended
  depth of field for high magnifications

• Phenotypic characterization
  of test compounds
• Target identification
• Protein localization
• Functional studies
• Antibody characterization

Live cell assays

• Variable temperature control (up to 42°C)
• Environmental control module
• 3 transmitted light modes
• Accurate xy staging - better cell tracking
• Hardware optimized for optical performance
  - reduced exposure times
• Cell tracking software
• Fast hardware autofocus

• Insect cells
• Heat-shock studies
• Time-course analysis
• Temperature-sensitive mutations
• Cell migration
• Cell lineage/cycle studies
• Stem cells
• Kinetic studies
• Predicitive toxicology

Rare event analysis

• Whole well imaging
• Large chip CCD camera
• 2x and 4x objectives
• Preview Scan - rapid location
  of region of interest
• Image overlap for stitching

• Stem cell assays
• Spheroids
•  Colony assays
• Small organisms
• Tissue studies
• Lineage analysis

3D analysis

• Accurate Z-staging
• Quantitatively accurate 3D stacks with
   confocal-like image quality
• Image restoration options for maximum
  resolution in lateral & axial dimensions

• Spheroids
• Tissue sections
• Small organisms (zebrafish,
  C. elegans, Xenopous oocytes etc)
• Stacks suitable for 3D volume rendering
  and reconstruction of organelles, tissues etc

Slide imaging

• New intuitive graphical user interface
• PreView Scan mode - rapid
  location of region of interest
• Smart software autofocus algorithm
  for accuracy & exceptional speed
• Automated objective changing
• Image stitching

• Investigative microscopy
• Small organisms
• Cell arrays
• Tissue arrays